Designed to relieve overpressure in a piping system containing compressible or incompressible fluids.
It is the preferred solution for automatically relieving overpressure in boilers, pressure vessels or other systems when the pressure and / or temperature exceeds the allowable limits.
Design in accordance with ASME B16.34 design requirements.
Bronze safety valve classes: 250 x 300 (steam) 350 (air).
Bronze relief valve classes: 300 psig except NPS 3 which is 150 psig.
BRONZE SAFETY RELIEF VALVE
In-plant calibration as per customer's requirements.
Manufactured in bronze in accordance with ASTM B62 grade 83600.
Manual lifting mechanisms are available for maintenance or system verification purposes.
Safety valves distinguished by their rapid opening or closing. Typically used for gas or steam pressure control.
Relief valves characterized by their gradual opening and closing. Commonly used for fluid pressure control.
Cast iron refurbishing qualified in accordance with ASME B16.34 radiographic requirements
OVERVIEW
Designed to relieve overpressure in a piping system containing compressible or incompressible fluids.
DESIGN FEATURES
Design features Bronze safety relief valves (gas or air service).
Design in accordance with ASME B16.34 design requirements.
Side discharge to recovery line, service line or to atmosphere.
NPT (male) threaded inlet connection in accordance with ASME B1.20.1.
NPT (female) threaded outlet connection in accordance with ASME B1.20.1.
Minimum calibration pressure at 0.35 kg / cm2 (5 psig).
Maximum calibration pressure with steam Model 2B10: 17.58 kg / cm2 (250 psig) Maximum calibration pressure Model 2B10-3: 21,10 kg / cm2 (300 psig).
Maximum calibration pressure with air or gas Model 2B10: 21,10 kg / cm2 (300 psig). Maximum calibration pressure with air, or gas Model 2B10-3: 24,61 kg / cm2 (350 psig).
Model 2B10 Maximum operating temperature: 208 ° C (406 ° F). Model 2B10-3 Maximum operating temperature 215 ° C (420 ° F).
Available with soft seat.
Design features Bronze relief valves (served with non-corrosive bronze fluids).
Design in accordance with ASME B16.34 design requirements.
Side discharge (to recovery line or service line).